Technical Specifications 60pMEA100/30iR-Ti
Temperature compatibility 10 - 50 °C
Dimension (W x D x H) 49 mm x 49 mm x 1 mm
Base material Polyimide foil (2611) on glass or ceramic carrier
Perforation:
Diameter of innermost area 2 mm
Total area of holes 19% (according to 2 mm)
Diameter of holes 5, 6, 7.5, 9, 10, 12.5, 15, 17.7, 20
Contact pads TiAu (Titan, Gold)
Track material TiAuTi (Titan, Gold, Titan)
Electrode diameter 30 μm
Interelectrode distance (centre to centre) 100 μm
Electrode height Planar
Electrode type TiN (Titanium nitride)
Isolation type Polyimide foil (2610) isolator
Electrode impedance 30 - 50 k
Electrode layout grid 6 x 10
Number of electrodes 60
Reference electrodes with internal reference (iR)
MC_Rack
Source layout in “Data Source Setup” 2 dim. (MEA)
Channel map pMEA 6x10.cmp
Cleaning Rinse with distilled water. Do not use ultrasonic bath!
These pMEAs are not heat stable, and should not be autoclaved!
MEA perfusion chamber (w/o) Without ring
(gr) Glass ring: ID +/- 19 mm, OD 24 mm, height 6 / 12 mm
(pr) Plastic ring without thread: ID 26.5 mm, OD 30 mm, height 6 / 3 mm
(pr-T) Plastic ring with thread: ID 26 mm, OD 30 mm, height 6 / 15 mm
Perforated Microelectrode Array with 6 x 10 electrode layout grid. Perforated MEAs for use with MEA1060 amplifiers
equipped with a perfusion ground plate (PGP) or a MEA2100 headstage with a perfusion element (PE). The perforation
allows a perfusion of the tissue from both sides of the pMEA.
60pMEA100/30iR-Ti
60pMEA100/30iR-Ti
Vue de la page 0
1 2

Résumé du contenu

Page 1 - 60pMEA100/30iR-Ti

Multi Channel SystemsMCS GmbHAspenhaustrasse 2172770 ReutlingenGermanyFon +49-7121-9 09 25- 0Fax +49-7121-9 09 [email protected]

Page 2

Multi Channel SystemsMCS GmbHAspenhaustrasse 2172770 ReutlingenGermanyFon +49-7121-9 09 25- 0Fax +49-7121-9 09 [email protected]

Commentaires sur ces manuels

Pas de commentaire